End of season is here, and the question we get most is whether Verdi hardware needs to come out for winter. For nearly everything, it doesn't.

We've published the full winterization procedure covering Gateways, Block Controllers, soil moisture sensors, SDI-12 telemetry nodes and pressure sensors.

The essentials:

• Pause schedules and confirm every valve reports closed before removing any battery. Latching solenoids hold their last position without power.

• Remove the 9V battery from each Block Controller. It will show offline until spring. That's expected.

• Leave the Gateway, soil sensors and telemetry nodes installed. They're rated for winter.

• Water-filled tensiometers come out. So do pressure sensors on lines that can't be fully drained.

Winter soil readings run dry because frozen soil reads drier than it is, and solar sites can drop offline in cold spells. Neither means a device has failed.